Electric Control + Hydraulic Transmission Technology JK203H

The electric hydraulic operating table is one of the core pieces of equipment in modern operating rooms. Relying on electric control and hydraulic transmission technologies, it offers advantages such as precise adjustment, stable load-bearing capacity, and robust safety features. It can be adapted to a variety of surgical settings across multiple specialties. Its core functions revolve around adjusting surgical positions, ensuring operational convenience, enhancing patient safety, and guaranteeing device compatibility.

Service Support:

  • Product Description
  • I. Performance Characteristics:

     

    1. Equipped with electro-hydraulic drive, the electric operating table features adjustable table surface elevation and lowering, as well as forward/backward movement. Rear tilt, left/right tilt, longitudinal   Translation: Translation function for forward movement and backboard folding. The tabletop motion is driven by ≥5.   Hydraulically operated by an independent hydraulic cylinder.

     

    2. Suitable for orthopedics, urology, thoracic surgery, kidney surgery, and other specialties that require coordination.   C   Type Arm, X   Optomechanical use Department.

     

    3. The surface structure of the electric operating table is entirely modular, allowing for easy matching to suit different types of surgeries.   The corresponding action module is all that’s needed.

     

    4. All-carbon fiber surgical backboard, 360°   °All-transparent structure, Length ≥ 1200 mm.

     

    5. The surface structure of the electric surgical table is entirely modular, allowing for easy matching to suit different types of surgeries.   The corresponding action module is all that’s needed.

     

    6. The electric operating table features a modular design, consisting of a headboard, a large backboard, and a small backboard. Consisting of a board, seat board, and leg board,   Dual-backplate design, electrically adjustable backplate (extension plate) ), Electrically adjustable upward and downward folding, as well as electric left-right tilting.

     

    Dual backplates allow for free switching; a dedicated interface for the spinal system is provided, truly enabling one bed to serve three purposes—free switching between backplates and the spinal system.   The system can be linked with the operating table.

    7. The electric operating table is equipped with an electric caster locking system that ensures the casters do not touch the floor during surgery, enabling stable support on the floor.   Hold on.

     

    8. Both the power cord connections for the electric operating table and the power cord connections for the manual controller utilize aviation plug designs, which are waterproof and dustproof.   Shedding.

     

    9. Electric operating table surface frame, linear guide rails, upright posts, and base All seats are equipped with  304  Made of stainless steel, impact-resistant. Impact-resistant, corrosion-proof, and disinfectant-resistant; featuring a sandblasted anti-glare finish that reduces eye strain for medical staff and makes cleaning convenient. Clean and disinfect.

    10. Used in electric operating tables   T   Modular base design, chassis <100 Hmm, it can be fully compatible.   G   Arm type, X   Optomechanics   Use. For   C   The arm support features ample working space, leaving sufficient room for the medical staff performing the procedure to move their feet.   Ensure the surgical table remains balanced and stable when performing various movements.

    11. The electric surgical table mattress is made entirely of soft, double-layer memory foam with a thickness of ≥ 75mm, using ≥  30mm  Memory foam and ≥45mm   High-density sponge. Mattress seam Uses seamless heat-sealing technology for waterproof and breathable performance.   Easy to clean, antistatic.

    12. The maximum noise level during normal operation of the electric surgical table’s hydraulic system shall not exceed:   60 dB.

     

    13. The orthopedic traction frame features a dual-joint design (both the upper arm and lower arm are made of carbon fiber with透视 properties). ), Can be completed.   Adjust from different angles.

     

    14. Features padded inner-thigh support posts.

     

    15. Equipped with a trailer hitch accessory vehicle.

     

    II. Technical Parameters:

     

    1. Length of the electric operating table surface 2500 mm.

     

    2. Electric operating table surface width: 550 mm.

     

    3. Countertop height (adjustable) ): 680mm–980mm (electric) ); Lift travel: 300m m.

     

    4. Front-to-back adjustment:   ≥30° (Electric).

     

    5. Left-right adjustment:   ≥30° (Electric).

     

    6. Headboard adjustment up/down ≥50°/90° (manual).

     

    7. Backplate adjustment up/down ≥90°/40° (electric).

     

    8. Footplate adjustment up/down ≥50°/90° (electric).

     

    9. The footplate’s horizontal angle ≥ 180°.

     

    10. Longitudinal translation of the bed surface (toward the head)   ≥300mm.

     

    11. Traction frame length:   ≥1750mm.

     

    12. Traction frame width: 120 mm to 750 mm.

     

    13. Traction device traction stroke:   ≥200mm (hand) Dynamic adjustment).

     

    14. Traction shoes: Ankle fixation seat available   360° rotation and free positioning.

     

    15. Adjustable angle of the traction device: The up-and-down tilt angle is adjustable to ≥25°. ±2°.

     

    16. Maximum traction displacement:   ≥1260mm.

     

    17. Maximum Traction Force:   ≥400N.

     

    18. Angle between the two arms: 0° to 180°.